BICON SHORT® IMPLANTS provide dentists with flexible solutions in challenging clinical situations. Their shorter lengths enable clinicians to confidently avoid vital structures, often eliminating the need for numerous grafting procedures.
With Bicon, the notion that longer implants are always better is challenged. In many cases, shorter implants prove to be the more advantageous solution, addressing clinical needs more effectively.
- Avoid vital structure
- Minimize bone grafting procedures
- Maximize implant placement possibilities
- Increase patient acceptance
- Offer a clinically-proven, comprehensive solution
- Offer single unit restorations without splinting
3.0mm and 4.0mm Diameter Implants
Description | Length | Well | Part Number |
---|---|---|---|
NARROW® 3.0mm Integra-CP® Implant | 6.0mm | 2.0mm | 260-330-206 |
NARROW® 4.0mm Integra-CP® Implant | 5.0mm | 2.0mm | 260-340-005 |
MAX 2.5® 4.0mm Integra-CP® Implant | 5.0mm | 2.5mm | 260-340-255 |
MAX 2.5® 4.0mm Integra-CP® Implant | 6.0mm | 2.5mm | 260-340-256 |
4.5mm Diameter Implants
Description | Length | Well | Part Number |
---|---|---|---|
4.5mm Integra-CP® Implant | 5.0mm | 3.0mm | 260-345-305 |
4.5mm Integra-CP® Implant | 6.0mm | 3.0mm | 260-345-306 |
4.5mm Integra-Ti® Implant | 6.0mm | 3.0mm | 260-145-306 |
5.0mm Diameter Implants
Description | Length | Well | Part Number |
---|---|---|---|
5.0mm Integra-CP® Implant | 5.0mm | 3.0mm | 260-350-305 |
5.0mm Integra-CP® Implant | 6.0mm | 3.0mm | 260-350-306 |
5.0mm Integra-Ti® Implant | 6.0mm | 3.0mm | 260-150-306 |
6.0mm Diameter Implants
Description | Length | Well | Part Number |
---|---|---|---|
6.0mm Integra-CP® Implant | 5.0mm | 3.0mm | 260-360-305 |
6.0mm Integra-CP® Implant | 6.0mm | 3.0mm | 260-360-306 |
6.0mm Integra-Ti® Implant | 5.0mm | 3.0mm | 260-160-305 |
Avoid Vital Structures: Inferior Alveolar Canal
9 Years
Three 5.0 x 6.0mm SHORT® Implants supporting three extra-orally cemented crowns for restoring the posterior mandible. Note level of inferior alveolar canal.
9 Years
Two 5.0 x 6.0mm SHORT® Implants
supporting two extra-orally cemented crowns for two mandibular right molars. Note level of inferior alveolar canal.
10 Years
A 6.0 x 6.0mm SHORT® Implant
supporting an extra-orally cemented crown for a mandibular left first molar.
12 Years
A 6.0 x 6.0mm SHORT® Implant
supporting an extra-orally cemented crown for a mandibular left first molar.
Avoid Vital Structures: Maxillary Sinus
9 Years
A 5.0 x 6.0mm SHORT® Implant supporting an extra-orally cemented crown for a maxillary left second molar. Note level of maxillary sinus.
11 Years
A 6.0 x 6.0mm SHORT® Implant supporting an extra-orally cemented crown for a maxillary left first molar. Note level of maxillary sinus.
12 Years
A 6.0 x 6.0mm SHORT® Implant
supporting an extra-orally cemented crown for a maxillary right first molar. Note level of maxillary sinus.
17 Years
A 6.0 x 6.0mm SHORT® Implant
supporting a PFM crown for a maxillary right first molar. Note level of maxillary sinus.
Plateau Design
20 Years
23 Years
18 Years
Bone Gain Over Time
2006
2010
2003
2012
2.0mm Healing Plug Inserter
Description | Length | Part Number |
---|---|---|
2.0mm Healing Plug Inserter* | 16.0mm | 260-100-002 |
* Included with each implant with a 2.0mm Well.
2.5mm Healing Plug Inserter
Description | Length | Part Number |
---|---|---|
2.5mm Healing Plug Inserter* | 16.0mm | 260-100-025 |
* Included with each implant with a 2.5mm Well.
3.0mm Healing Plug Inserter
Description | Length | Part Number |
---|---|---|
3.0mm Healing Plug Inserter* | 16.0mm | 260-100-001 |
* Included with each implant with a 3.0mm Well.
Implant Selection
- All implants are packaged with a healing plug.
- The choice of implant length and width depends upon available bone and expected occlusal loads.
- For an aesthetic emergence profile, the Bicon Implant is designed to be placed below the crest of the alveolar ridge to the extent that the implant is 5.0mm below the facial crest of the gingiva.
- The implant may be placed at or slightly above the alveolar crest, if an aesthetic emergence profile is not a concern.
- In general, choose the widest but not necessarily the longest implant the bone will allow.
- Posteriorly to the canine, place one implant per tooth if practical.
- See reference for depth indicators on the 2.0mm pilot drill and the latch reamers.
SHORT® Implant Literature: