Non-Shouldered Abutments

With 0°, 15°, and 25° angled abutments and over 18 different sizes to choose from, the non-shouldered abutment is one of Bicon’s most versatile. Since it is a solid abutment, it can be prepared either intra-orally or extra-orally. The new Restorative/Laboratory kits (consisting of two sleeves and a transfer die) will facilitate impression taking, temporization, wax-ups, and the fabrication of corrective copings. The impression sleeves snap definitively onto the new non-shouldered abutments and are color coded according to the diameter of the abutment: 4.0mm = red, 5.0mm = yellow, 6.5mm = green and 7.5mm = purple.

Non-Shouldered Abutment Measurement Guide

NonSho Abutment Measurement Guide 1a

Non-Shouldered Abutments with a 3.0mm Post

3.0mm Non-Shouldered Abutments 1a
DescriptionDiameterHeightAnglePostPart Number
4.0 x 6.5mm 0° Abutment 3.0mm Post4.0mm6.5mm3.0mm260-340-001
4.0 x 6.5mm 15° Abutment 3.0mm Post4.0mm6.5mm15°3.0mm260-340-015
4.0 x 10mm 0° Abutment 3.0mm Post4.0mm10mm3.0mm260-340-101
4.0 x 10mm 15° Abutment 3.0mm Post4.0mm10mm15°3.0mm260-340-115
5.0 x 5.0mm 0° Abutment 3.0mm Post5.0mm5.0mm3.0mm260-350-050
5.0 x 5.0mm 15° Abutment 3.0mm Post5.0mm5.0mm15°3.0mm260-350-055
5.0 x 6.5mm 0° Abutment 3.0mm Post5.0mm6.5mm3.0mm260-350-001
5.0 x 6.5mm 15° Abutment 3.0mm Post5.0mm6.5mm15°3.0mm260-350-015
5.0 x 6.5mm 25° Abutment 3.0mm Post5.0mm6.5mm25°3.0mm260-350-025
5.0 x 10mm 0° Abutment 3.0mm Post5.0mm10mm3.0mm260-350-101
5.0 x 10mm 15° Abutment 3.0mm Post5.0mm10mm15°3.0mm260-350-115
5.0 x 12mm 0° Abutment 3.0mm Post5.0mm12mm3.0mm260-350-201
5.0 x 12mm 15° Abutment 3.0mm Post5.0mm12mm15°3.0mm260-350-215
6.5 x 5.0mm 0° Abutment 3.0mm Post6.5mm5.0mm3.0mm260-365-050
6.5 x 5.0mm 15° Abutment 3.0mm Post6.5mm5.0mm15°3.0mm260-365-055
6.5 x 6.5mm 0° Abutment 3.0mm Post6.5mm6.5mm3.0mm260-365-001
6.5 x 6.5mm 15° Abutment 3.0mm Post6.5mm6.5mm15°3.0mm260-365-015
7.5 x 8.0mm 0° Abutment 3.0mm Post7.5mm8.0mm3.0mm260-375-801
7.5 x 8.0mm 15° Abutment 3.0mm Post7.5mm8.0mm15°3.0mm260-375-815

Non-Shouldered Abutments with a 2.5mm Post

2.5mm Non-Shouldered Abutments 1a
DescriptionDiameterHeightAnglePostPart Number
4.0 x 6.5mm 0° Abutment 2.5mm Post4.0mm6.5mm2.5mm260-240-001
4.0 x 6.5mm 15° Abutment 2.5mm Post4.0mm6.5mm15°2.5mm260-240-015
4.0 x 6.5mm 25° Abutment 2.5mm Post4.0mm6.5mm25°2.5mm260-240-025
4.0 x 10mm 0° Abutment 2.5mm Post4.0mm10mm2.5mm260-240-101
4.0 x 10mm 15° Abutment 2.5mm Post4.0mm10mm15°2.5mm260-240-115
5.0 x 6.5mm 0° Abutment 2.5mm Post5.0mm6.5mm2.5mm260-250-001
5.0 x 6.5mm 15° Abutment 2.5mm Post5.0mm6.5mm15°2.5mm260-250-015
5.0 x 6.5mm 25° Abutment 2.5mm Post5.0mm6.5mm25°2.5mm260-250-025
5.0 x 10mm 0° Abutment 2.5mm Post5.0mm10mm2.5mm260-250-111
5.0 x 10mm 15° Abutment 2.5mm Post5.0mm10mm15°2.5mm260-250-115

Non-Shouldered Abutments with a 2.0mm Post

2.0mm Non-Shouldered Abutments 1a
DescriptionDiameterHeightAnglePostPart Number
4.0 x 6.5mm 0° Abutment 2.0mm Post4.0mm6.5mm2.0mm260-140-002
4.0 x 6.5mm 15° Abutment 2.0mm Post4.0mm6.5mm15°2.0mm260-140-015
4.0 x 6.5mm 25° Abutment 2.0mm Post4.0mm6.5mm25°2.0mm260-140-025
4.0 x 10mm 0° Abutment 2.0mm Post4.0mm10mm2.0mm260-140-101
4.0 x 10mm 15° Abutment 2.0mm Post4.0mm10mm15°2.0mm260-140-115
5.0 x 6.5mm 0° Abutment 2.0mm Post5.0mm6.5mm2.0mm260-150-001
5.0 x 6.5mm 15° Abutment 2.0mm Post5.0mm6.5mm15°2.0mm260-150-015
5.0 x 6.5mm 25° Abutment 2.0mm Post5.0mm6.5mm25°2.0mm260-150-025
5.0 x 12mm 0° Abutment 2.0mm Post5.0mm12mm2.0mm260-150-201
5.0 x 12mm 15° Abutment 2.0mm Post5.0mm12mm15°2.0mm260-150-215

Non-Shouldered Abutment Considerations

  • The abutment can be rotated 360˚ to reach a desired position or to achieve parallelism prior to being seated.
  • The 4.0mm abutments are primarily used for maxillary laterals and bicuspids; 5.0mm abutments are more universal in their use; 6.5mm and 7.5mm abutments are ideally suited for molars.
  • The diameter of each Emergence Cuff corresponds to the diameter of a non-shouldered abutment.
  • Do not make an impression with the emergence cuff.
  • Choose the widest abutment and sleeve (see below) that will support the interproximal papillae without encroaching upon them.

Restorative/Laboratory Kits for Non-Shouldered Abutments*

Restorative Laboratory Kits 1a
DescriptionDiameterHeightPart Number
4.0 x 6.5mm Non-Shouldered Restorative/Laboratory Kit4.0mm6.5mm260-140-465
4.0 x 10mm Non-Shouldered Restorative/Laboratory Kit4.0mm10mm260-140-410
5.0 x 5.0mm Non-Shouldered Restorative/Laboratory Kit5.0mm5.0mm260-150-450
5.0 x 6.5mm Non-Shouldered Restorative/Laboratory Kit5.0mm6.5mm260-150-465
5.0 x 10mm Non-Shouldered Restorative/Laboratory Kit5.0mm10mm260-150-410
5.0 x 12mm Non-Shouldered Restorative/Laboratory Kit5.0mm12mm260-150-412
6.5 x 5.0mm Non-Shouldered Restorative/Laboratory Kit6.5mm5.0mm260-165-450
6.5 x 6.5mm Non-Shouldered Restorative/Laboratory Kit6.5mm6.5mm260-165-465
7.5 x 8.0mm Non-Shouldered Restorative/Laboratory Kit7.5mm8.0mm260-175-480

*Each kit contains (1) Transfer Die, (1) Impression/Waxing Sleeve, and (1) Temporization Sleeve.

Temporization Sleeve for Non-Shouldered Abutments

Temporization Sleeves 1a
DescriptionDiameterPart Number
4.0mm Non-Shouldered Temporization Sleeve (2)4.0mm260-140-165
5.0mm Non-Shouldered Temporization Sleeve (2)5.0mm260-150-165
6.5mm Non-Shouldered Temporization Sleeve (2)6.5mm260-165-165
7.5mm Non-Shouldered Temporization Sleeve (2)7.5mm260-175-165

Non-Shouldered Prosthetic Component Considerations

  • The impression sleeves and transfer dies are color coded according to the corresponding diameter of the non-shouldered abutment:
    4.0mm = red, 5.0mm = yellow, 6.5mm = green, and 7.5mm = purple.
  • The sleeves may be used for impression making, temporization, corrective copings, and/or as waxing sleeves.
  • The temporization sleeves may be used in lieu of the emergence cuffs.
  • Always confirm the complete seating of snap-on sleeves with either the non-shouldered abutment or colored abutment transfer die.
  • It is paramount that the proper abutment transfer die height be chosen for pouring of a stone model, since all transfer dies of the same color will snap into an impression sleeve of that color.
  • The diameter and height of the transfer dies are sized to match the diameter and height of a corresponding non-shouldered abutment.
  • Although possible, avoid making an impression using the tooth colored temporization sleeves, since they are not color coded with their corresponding transfer dies and they are more retentive.
  • Sleeves may be easily modified to suit a particular clinical need.
  • Current versions of the non-shouldered abutment have a groove approximately 3.0mm above its height of contour providing retention for the new snap-on impression and temporization sleeves.
  • If a sleeve is used as a waxing sleeve, the internal snap ring should be removed with a bur.

Emergence Cuff for Non-Shouldered Abutments

DescriptionDiameterPart Number
4.0mm Emergence Cuff (4)4.0mm260-140-010
5.0mm Emergence Cuff (4)5.0mm260-150-010
6.5mm Emergence Cuff (4)6.5mm260-165-065
Emergence Cuffs 1a

Emergence Cuff Considerations

  • The diameter of each emergence cuff corresponds to the diameter of a non-shouldered abutment.
  • Do not make an impression with an emergence cuff.
  • If you prefer to make an impression of a non-shouldered abutment with a plastic sleeve, please refer to above, Restorative/Laboratory Kits for Non-Shouldered Abutments, section.